Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY!

MAY 2013
Przeglądanie stron 0
1 2 3 4 5 6 ... 22 23

Podsumowanie treści

Strona 1 - 

Web Address: www.oldcastlebe.comPhone: 1-866-OLDCASTLE (653-2278)Note: Installation and Glazing Manuals are product specific. FOR R

Strona 2

FIGURE 2Shear block sealantApply sealant toshear blocks at interiorand exteriorFS-71/2"7/8"7/8"Drill #11 (.191Ø)Holes & Countersink

Strona 3

DOOR FRAME ASSEMBLYSeal shear blocksas shown(4) FS-9 (#14 X 1-1/2" HHSTS)(2) AC-130FIGURE 5Common LockMullionPhone: 1-866-OLDCASTLE (653-2278)Web

Strona 4

DOOR FRAME ASSEMBLY(4) AC-130(8) FS-9 (#14 X 1-1/2" HHSTS)Seal shear blocksas shownFIGURE 6Common HingeMullionNote:When using the common hingemul

Strona 5

Series 3000 XT DOOR FRAME ASSEMBLY1. When installing 3000 XT door frame without transom use AD-454 jambs and door header2. Attach (2) AC-133-

Strona 6

Series 3000 XT DOOR FRAME ASSEMBLY1. Door frame with transom will use AD-454 door jambs, AD-455 door header with AD-406 and AD-407vertical sash. T

Strona 7

DOOR FRAME INSTALLATION1. Door frame shall be completely assembled, including threshold; with all joints neatly aligned andtight. See pages 7 th

Strona 8

DOOR FRAME INSTALLATION(1) FS-62#10-32 x 1/4" ucpfhTH-61ThresholdMark lines to locatefront and back ofthresholdApply bead of sealantfull length o

Strona 9

DOOR FRAME INSTALLATION1. Install GP-155 mid-seal gasket into race in thermal composite strut. Use light soapywater or window cleaner to assist in

Strona 10 - AD-375 THERMAL DOOR

DOOR FRAME INSTALLATIONGP-155 GasketSeal at thresholdBed Door Stopin Sealant alongfront leg.Bed threshold in sealantand seal at ends to doorjamb, door

Strona 11

DOOR GLASS INSTALLATIONGlass setting blocks are installed in their proper positions at the factory. Glazing prior to installation ispossible (step 1).

Strona 12

General Information SheetProduct Use

Strona 13

INSTALLATION OF OFFSET HUNG DOOR ON BUTT HINGESBack-up plates are installed in the door and the frame at the factory. Butt hinges should be installed

Strona 14

FINAL ADJUSTMENTS TO DOORAfter door is installed, check clearances. The top rail should be a consistent 1/8" below the header. Thebottom of door

Strona 15

INSTALLATION PAIRS OF DOORS Located at the meeting stile of the pair of AD-375 thermal doors are threeadjustable astragals. The exterior astrag

Strona 16

AD-450AD-451AD-4521" Subframe2" Common LockMullion5 1/4" Common HingeMullionDoor Frame MembersTop Rail Sealw/ GP-157 Gasket1" Door

Strona 17

The AD-375 Thermal Doors are intended for installation by glazing professionals with appropriate experience.Subcontractors without experience should e

Strona 18

Check glass dimensions for overall size as well as thickness. Oldcastle BuildingEnvelope cannot be heldresponsible for gaskets that are not water ti

Strona 19

DOOR & FRAME CHECKLISTInspect door to make sure no damage occurred in shipping. The door should have a seal installed in thetop rail and also a sw

Strona 20

Thermal doors are available as a single, pair or sets of single doors that are separated by a 2" commonlock or 5 1/2" hinge jamb. Two option

Strona 21

44 1/8"39 3/8"41 15/16"41 11/16"Center Line of PanicCenter Line of CylinderCenter Line of Push BarCenter Line of CylinderStandard

Strona 22

Hand and Details of Doors -- U.S. Standardization ProcedureThermal Doors are available as Out Swing only. For Hardware: Left Hand, Reverse Bevel (LHR)

Strona 23

DOOR FRAME ASSEMBLY1. Attach (2) AC-133-01 shear blocks to top end of door jambs using (4) FS-9 #14 x 1 1/2" hexhead fasteners. See FIGURE